The HP V series answers to the demands of on board compactness. The vertical conception of the plant enables the system to fit into tight places. With the base frame measuring only 47 by 28 cm with a height of 60 cm, the unit installation space is minimal. MODBUS protocol is supplied as standard.
Produces 200 Lt/h of water.
Available voltages 110V 60Hz – 230V 50Hz – 230V 60Hz – 380V 50Hz – 440V 60Hz
This unit is composed as follows:
1 X 3 way valve PVC flushing system
1 X AISI 316 L stainless hand operated pressure regulation valve
1 X AISI 316 LOWARA 2HMS3 booster pump
1 X AISI 316 High Pressure Pump W99
3 X AISI 316 Pressure Vessels 2540
3 X DOW CHEMICAL or HYDRANAUTICS membranes – SW30 2540
1 X AISI 316 Removable electric switchboard case
1 X PLC controlled Electrical Switchboard – with settable parameters and DIAGNOSTIC SYSTEM*
1 X Alarmed PRESSURE Control System (min 20 – max 60 bar), to protect pumps and membranes
1 X Alarmed SALINITY Control System (400uS), for the not conforming water automatic drain and timed stop
1 X Analogical Gauge Meter
1 X Digital Gauge Meter (pressure sensor)
1 X Digital Flow meter
1 X Cartridge Inlet Double Pre filtration (Charcoal + 5 micron)
MODEL |
V200 MANUAL |
Flow rate Lt/h
Nominal flow rate Lt/h |
200 249 |
Daily flow rate Lt/day
Nominal flow rate Lt/day |
4800 5976 |
Conductivity permeate uS |
400 |
Installed Power kW |
2,2 |
Total Weight Kg |
104 |
The flow rates are calculated for a treated water with 35000 ppm at 25°C at 60 Bar
ABSORBED CURRENT at 230v 50Hz |
V200 MANUAL |
High Pressure pump |
12 A |
Low Pressure pump |
3 A |
CONNECTIONS |
V200 MANUAL |
Sea water inlet |
½” |
Tank inlet (for washing) |
½” |
Concentrate drain |
¼”-10 mm |
Permeate outlet |
¼”-10 mm |
Not conforming water outlet |
¼”-10 mm |
OVERALL MACHINE DIMENSIONS |
V200 MANUAL |
Width
Height Depth |
550 mm 600 mm 280 mm |
OVERALL MEMBRANES DIMENSIONS |
V200 MANUAL |
Width
Height Depth |
1100 mm 290 mm 100 mm |
Delivery 7 to 10 days from order.